PARKLEX FACADE - SPECIFICATIONS
Printer
Friendly Version: Parklex Facade Product Specifications [25k]
Adobe Acrobat® Reader is required.
Get
it here for free.
SECTION 07430 - EXTERIOR GRADE WOOD COMPOSITE PANEL
* NOTE TO SPECIFIER:
Distributed by: Finland Color Plywood Corporation
Corporate Headquarters
1310 Main St.
Venice, CA 90291
Bus: (310) 396-9991
Bus Fax: (310) 396-4482
E-mail: info@fcpcusa.com
Warehouses in Los Angeles, CA & Port Newark, NJ
http://www.fcpcusa.com/
Manufactured by: Composites Gurea, S.A.
Zalain Auzoa 13
31780
Vera de Bidasoa, Navarra
Spain
http://www.parklex.com/
Parklex Facade is a prefinished exterior grade wood composite panel. This HIGH QUALITY panel system has been treated with durable THERMO-HARDENED resins and has a bakelite core. The panel is dimensionally stable and is suitable for exterior applications. Minimum maintenance is required; clean with water and non-abrasive cleaner. Parklex Facade is highly resistant to varying climatic conditions, including freeze/thaw, salt spray, dry climate and UV ray exposure. However, due to the panel being composed of wood and other natural materials, its appearance may change over time. It is non-toxic and resists mold, mildew, fungus and is impervious to termite. Parklex Facade In 2003, improvements to the Parklex Facade were put into production. The improvements increase the age resistance and dimensional stability of the panel. An additional layer of clear film, developed by the scientists at Parklex, greatly increase the UV resistance and color stability of the face veneer. Additionally, the surface gloss of the finish is retained, showing no sign of change during artificial ageing testing. The improvements also add increased protection against humidity absorption, increasing the dimensional stability of the panel.
PART 1 - GENERAL
1.1 WORK
A. Provide everything required to complete the work as shown on the
Drawings and specified herein.
1.2 QUALITY STANDARDS
A. Provide experienced, well-trained workers competent to complete
the work as specified. Fabricator/installer shall be experienced in
performing work of similar type and scope.
B. Unless approved by the Architect, provide all related products and
accessories from one manufacturer.
C. Ventilated rainscreen system shall provide complete secondary drainage
system, draining at base of wall. Supporting substrate for exterior
wall panels shall comply with all current codes and regulations.
1.3 SUBMITTALS
A. Submit the following within 30 calendar days after receiving the
Notice to Proceed.
*Note to specifier: Submittals are usually required within a specified
number of calendar days after the Contractor is given the Notice to
Proceed. 30 calendar days is a common requirement for medium- to large-size
projects. Your choice of time will depend on the size of the project
and the Owner's need for an expedited schedule.
B. Submit list of materials to be provided for this work; manufacturer's
data required to prove compliance with these Specifications, manufacturer's
installation instructions; shop drawings of the ventilated rainscreen
system, as required, with complete details and assembly instructions.
C. Submit samples as required for approval by the Architect.
*Note to specifier: Samples may be requested with a different time limit
than other submittals. Details of the samples requested -- sizes, finishes,
etc. -- are usually specified. Delete selection samples if colors have
already been selected.
D. Shop Drawings for Ventilated Rainscreen System: Shop Drawings shall
be complete with specific instructions for the installation of panels,
sub-frame assemblies and other component parts. Include engineering
analysis. Drawings shall indicate sizes of ventilation openings and
methods of preventing unwanted insects or animals from entering cavity
behind panels.
1.4 PRECONSTRUCTION AND PREPARATION
A. Examine and verify that job conditions are satisfactory for speedy
and acceptable work.
B. Field Measurements: Secure field measurements before preparation
of shop drawings and fabrication where possible, for proper fabrication
and installation of the work.
C. Preinstallation Meeting: Conduct preinstallation meeting to verify
project requirements, substrate conditions, manufacturer's installation
instructions and manufacturer's warranty requirements.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Deliver materials in manufacturer's original, unopened, undamaged
containers with identification labels intact. Materials must be transported
flat and kept dry and protected from the elements and handled with care.
B. Storage and Protection: Materials must be stored flat and kept dry
in a warehouse/storage facility, protected from exposure to harmful
weather conditions, at temperatures and humidity conditions recommended
by the manufacturer.
1.6 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation)
within limits recommended by manufacturer for optimum results. Do not
install products under environmental conditions outside manufacturer's
absolute limits.
1.7 WARRANTY
A. Project Warranty: Refer to Conditions of the Contract for project
warranty provisions.
B. Factory Product Warranty: Submit, for Owner’s acceptance, factory’s standard limited ‘product only’ warranty document executed by authorized company official. Factory product warranty is in addition to, and not a limitation of, other rights Owner may have under Contract Documents.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Provide Parklex Facade [Exterior Grade Wood Composite Panels]
Distributed by: Finland Color Plywood Corporation
Corporate Headquarters
1310 Main St.
Venice, CA 90291
Bus: (310) 396-9991
Bus Fax: (310) 396-4482
E-mail: info@fcpcusa.com
Warehouses in Los Angeles, CA & Port Newark, NJ
http://www.fcpcusa.com/
Manufactured by: Composites Gurea, S.A.
Zalain Auzoa 13
31780
Vera de Bidasoa, Navarra
Spain
http://www.parklex.com/
B. Substitutions: Not Permitted.
2.2 MATERIALS
A. EXTERIOR GRADE WOOD COMPOSITE PANEL: Natural laminated wood panel, standard one sided, (front face only), Ayous or Boak wood coated with phenolic resins and UV resistive polymer film; inner core paper fibers treated with thermo-hardenend resins (bakelized core), balancing layer on back face (not designed for exposure to the elements). Two sided panel can be specially ordered.
1. WOOD VENEER:
ANP – Ayous Natural
ABP Lt. – Ayous Light Brown
ABP Dk. – Ayous Dark Brown
BNP – Boak Natural
BBP – Boak Brown
Smooth surface (standard).
* NOTE TO SPECIFIER: Delete veneers not used on the project.
2. PANEL DIMENSIONS:
1220mm (48") x 2440mm (96") x thickness.
Thickness: 3mm, 6mm, 8mm, 10mm, 12mm and 14mm.
* NOTE TO SPECIFIER: Delete thicknesses not used on the project.
3. DIMENSIONAL TOLERANCES:
Length ±2mm, Width ±2mm, Thickness ±0.55mm (10mm
thick panel).
4. WEIGHT:
2.23 lb/ft2 (8mm); 1220mm x 2440mm x 8mm panel weighs approximately
72 pounds.
2.8 lb/ft2 (10mm); 1220mm x 2440mm x 10mm panel weighs approximately
90 pounds.
* NOTE TO SPECIFIER: Delete thicknesses not used on the project.
5. SURFACE BURNING CHARACTERISTICS:
Report on surface burning characteristics determined by ASTM E-84
(twenty-five foot tunnel furnace test method), meets Class B (II)
- 75 or under flame spread, with a flame spread index of 40 and smoke
developed index of 35. It is possible to manufacture the product to
achieve a Class A (Class I) rating - with a flame spread index of
5 and smoke developed index of 10. Please contact us for additional
information.
6. THERMAL PROPERTIES
Parameter Description  |
Metric  |
English  |
|
| Thermal Conductivity k |
0.18 W/m·K |
0.104 (Btu/h)/ft·F |
| Thermal Resistance R (10mm) |
0.0556 K·m2/W |
0.315 h·ft2·F/Btu |
| Equivalent to R-9.61 (thermal resistance
of 1 ft of Parklex insulation, given in h·ft2·F/Btu). |
7. TECHNICAL DATA
| ASTM Test Results |
| Characteristics |
Standards and test methods |
Values |
|
| Density (10mm) |
ASTM D 2395 Method A |
1.51 g/cc |
| Moisture Content |
ASTM D 4442 Method A |
2.1% |
| |
| Water Absorption (24 h/23°C) |
ASTM D 1037 Method B |
0.34% by mass
0.56% by volume |
| |
| Thickness Swelling |
|
0.59% |
| |
| Flexural Properties |
ASTM D 1037 |
|
| Modulus of Elasticity |
|
| veneer parallel to long dimension |
dry
soaked |
19.0 GPa (2,756,000 psi)
18.0 GPa (2,611,000 psi) |
| veneer perpendicular to long dim. |
dry
soaked |
9.0 GPa (1,305,000 psi)
8.7 GPa (1,261,000 psi) |
| Bending Strength (MOR) |
|
| parallel to long direction |
dry
soaked |
193 MPa (28,000 psi)
200 MPa (29,000 psi) |
| perpendicular to long direction |
dry
soaked |
93 MPa (13,500 psi)
108 MPa (15,700 psi) |
| |
| Bond Durability |
APA PS-1 6.1.5 |
|
| maximum load |
reference
vacuum/pressure soaked
boiled (2 cycles) |
2.58 kN (580 lb-f)
3.47 kN (780 lb-f)
2.68 kN (600 lb-f) |
| Surface Burning Characteristics |
ASTM E-84 |
Class B (II) / Class A (I) |
| |
| Click on the following link for Interpretation
of ASTM Test Data on Parklex Facade. |

ASTM Testing Performed at AEWC Advanced Engineered Wood Composites
Center, University of Maine; ASTM E-84 Testing (Surface Burning) performed
at Hardwood Plywood & Veneer Association Laboratory, Reston Virginia. |
8. EUROPEAN TEST RESULTS
1. 061018 Nueva Norma de Clasificación EN
2. 061018 denominaciones parklex EN
3. P1000 EDS
4. P1000 EDF
5. P700 CGS
6. P700 CGF
7. P500 VDS
8. P500 VDF
9. P2000 HDS
10. P200 HDF
Printer
Friendly Version: Resistance
to Weathering [25k]
Adobe Acrobat® Reader is required.
Get
it here for free.
Resistance to fixings according to UNE-EN 438-7:2005 Part 4.5
Flexural strength according to UNE-EN 438-7:2005 Part 4.8
Durability according to UNE-EN 438-7:2005 Part 4.13.2.: Compact laminate panels for external use
Density in accordance with UNE-EN ISO 1183-1:2004, test method A
Resistance to humidity with UNE-EN 438-2:2005 Part 15
Water vapour permeability according to UNE-EN 438-7:2005 Part 4.4
Various tests
2.3 FABRICATION
A. Fabricate composite panels and accessory items in accordance with
manufacturer's recommendations and approved submittals.
B. Fabricate panels to sizes indicated.
PART 3 EXECUTION
3.1 INSPECTION
A. Examine alignment of backup structure prior to installing sub-frame.
Do not proceed until all defects are corrected.
3.2 INSTALLATION
A. Comply with Manufacturer’s “General Guidelines for
Panel Installation” available here.
B. Install solid exterior wall panels plumb and level and accurately
spaced in accordance with manufacturer's recommendations and approved
submittals.
C. Fasten solid exterior wall panels to supporting substrate with fasteners
[and adhesive] approved for use with adjoining construction.
D. Interface with Other Work:
* NOTE TO SPECIFIER: Include adjacent surfaces to which panels must
adjoin.
1. [Specify applicable requirements for interface with other work.].
E. Accessory Items: Install corner profiles, gaskets and trim [Insert
accessory items.] with fasteners and adhesive appropriate for use with
adjoining construction as indicated on drawings and as recommended by
manufacturer.
3.3 DAMAGED MATERIAL
A. Repair or replace all damaged material to the satisfaction of the
Architect.
3.4 CLEANING
A. Do not use abrasive cleaners or cleaning tools. Dry wipe down panel
sections as work progresses.
B. Provide final cleaning of the wall system.
3.5 PROTECTION
A. Protect installed product and finish surfaces from damage during
construction.
END OF SECTION
 |
|